§ 39-89. Irrigation plan requirements.
(a)
All multifamily and nonresidential uses shall require an irrigation plan which shall include the following:
(1)
A minimum scale of one (1) inch to twenty (20) feet;
(2)
The location of all surveyed existing and proposed trees, vegetation, or ecological communities to be preserved, as required and approved by the EPGMD (See Section 39-80);
(3)
The location and outline of existing and proposed buildings and site improvements, water bodies, and hardscape features such as driveways, sidewalks, pools, fountains, fences, and retaining walls;
(4)
The location of all on grade, underground, and overhead utilities;
(5)
The location of the nearest recycled or reuse water main within one thousand (1,000) feet of the nonresidential subject property;
(6)
The irrigation POCs, the design capacity, and the water service pressure at irrigation POCs;
(7)
The water meter size;
(8)
The major components and location of the irrigation system, including all pumps, filters, valves, and pipe sizes and lengths;
(9)
Reduced-pressure-principle backflow-prevention devices for each irrigation POC on potable water systems and specifications;
(10)
The locations and specifications of controllers of rain shut-off devices and soil moisture sensors;
(11)
A notation indicating that all landscape areas shall be provided with an automatically operating, underground irrigation system designed to have head-to-head coverage (one hundred percent (100%) coverage with one hundred percent (100%) overlap);
(12)
An irrigation legend with the following elements:
a.
Separate symbols for all irrigation equipment with different spray patterns, precipitation rates, and pressure compensating devices;
b.
General description of equipment, including the manufacturer's name and model number for all specified equipment;
c.
Recommended operating pressure per nozzle, bubbler, and low flow emitter;
d.
Manufacturer's recommended overhead and bubbler irrigation nozzle rating in gallons per minute, or gallons per hour for low flow point applicators;
e.
Minimum (no less than seventy-five percent (75%) of maximum spray radius) and maximum spray radius per nozzle; and
f.
Manufacturer's rated precipitation rate per nozzle at specified pounds per square inch (psi); and
(13)
Zone layout plan (minimum scale of one (1) inch to twenty (20) feet):
a.
Indicating head type, specifications, and spacing; and
b.
Indicating methods used to achieve compliance with landscape irrigation design standards, as required by Section 373.228, Florida Statutes.
(Ord. No. 2017-15 , § 18, 5-23-17)